EasyManuals Logo
Home>Go Power>Solar panel>GP-DURALITE-100

Go Power GP-DURALITE-100 User Manual

Default Icon
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
gpelectric.com | [page 17]
Further Steps (if required):
With the solar panel in sunlight, check the voltage at the controller solar panel terminals with a voltmeter.
If there is no reading at the controller solar panel terminals, the problem is somewhere in the wiring from the solar panel to the controller.
Current Reading: Less than expected
Time of Day: Daytime, clear sunny skies
Possible Causes:
1. Incorrect wiring connections.
2. Modules look dirty, overhead object is shading modules or it is an overcast day in which a shadow cannot be cast.
3. Dirty or shaded module or lack of sun.
Remedy:
1. Reconnect in correct conguration. Tighten all connections. Check wire to ensure no componet has become loose or frayed.
2 Clean modules, clear obstruction or wait for conditions to clear.
Avoid any shading no matter how small. An object as small as a broomstick held across the solar module may cause the power output to
be signicantly reduced. Overcast days may also cut the power output of the module.
Further Steps (if required):
Disconnect one or both panel wires from the controller. Take a voltage reading between the positive and negative panel wire. A single
12 volt module should have an open circuit voltage between 17 and 23 VDC. If you have more than one solar module, you will need to
conduct this test between the positive and negative terminals of each module junction box with either the positive or the negative wires
disconnected from the terminal.
LED Showing: Solid Red
Time of Day: Daytime
Cause and Remedy
The panel is not receiving enough sunlight. Move the panel into a better position to capture more sunlight.
LED Showing: Flashing Red
Time of Day: Daytime
Cause and Remedy
There is a short circuit or an improper connection. Disconnect from the battery, unplug any USB devices and close the panel. Re-open
the panel and try to reconnect all devices again.
®
TROUBLESHOOTING
14.4 SOLAR PANEL LED INDICATORS

Other manuals for Go Power GP-DURALITE-100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power GP-DURALITE-100 and is the answer not in the manual?

Go Power GP-DURALITE-100 Specifications

General IconGeneral
BrandGo Power
ModelGP-DURALITE-100
CategorySolar panel
LanguageEnglish

Related product manuals