1. SAFETY
Important safety information is contained throughout this manual that should be carefully observed and followed. This
information is presented using the following format:
The information is categorized in two ways:
Warning: Bodily harm could occur if instructions are not explicitly followed. If there are any doubts about the procedure or
conditions, please call GoPower! technical support before doing anything.
Caution: Damage to property could occur if instructions are not followed properly.
The following symbols are used to indicate the type of hazard.
GENERAL SAFETY
Read entire manual before installation
Any voltage above 30 VDC should be considered dangerous. Make sure power is disconnected before touching
terminals that exceed this voltage.
There are no parts inside the controller that need to be maintained or repaired. The controller shall never be disassembled
Unless otherwise specied, all terminal blocks should be re-tightened at least every 6 months to prevent possible re
caused by connections that have vibrated loose.
Ensure all connections are tight and secure. Loose connections may generate sparks and heat. Be sure to check
connections one week after installation to ensure they are still tight.
SOLAR CONTROLLER SAFETY
Always connect the battery BEFORE connecting the solar array to prevent damage to the controller. If the battery
wires need to be disconnected, the solar array wires should rst be disconnected.
To prevent damage to the controller, ensure the solar array voltage does not exceed the maximum voltage of the solar
controller. See specications table below to determine the limit for your controller.
BATTERY SAFETY
Ensure the battery type is set correctly in the controller settings to avoid possible explosion or re
Read manual for battery and observe safety precautions before connecting the battery to the controller
Only use deep cycle batteries that are intended for energy storage applications
Warning / Caution: Result
Description of condition leading to result
SYMBOL MEANING SYMBOL MEANING
General Warning Hot Surface
Risk of Shock Risk of Fire
Risk of Electrocution Risk of Chemicals
Risk of Explosion Risk of Eye Injury
SYMBOL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Go Power GP-RVC-MPPT-30 and is the answer not in the manual?

Go Power GP-RVC-MPPT-30 Specifications

General IconGeneral
Battery Voltage Range8V – 32V
Battery TypeLead Acid (AGM, GEL, Flooded), LiFePO4
Max Charge Current30A
Conversion Efficiency≤98%
MPPT Tracking Efficiency>99%
No-Load Loss<10mA
Max Panel Input Voltage100Voc
Max PV Power Input600W@12V / 1200W@24V
GroundingNegative
ProtectionSolar/battery reverse polarity Solar/battery over voltage Solar/battery short circuit Over temperature
Operating Temperature-35 to 45°C
Storage Temperature-35 to 75°C
Humidity95% N.C.
Water Ingress ProtectionIP32
Altitude< 3000m
Max Wire Gauge8 AWG
Weight and Dimensions IconWeight and Dimensions
Dimensions (H x W x D)3.15” x 7.78” x 5.5”
Weight3.14lbs (1.42kg)