08 System Commissioning
User Manual V1.0-2022-10-30
Previous page
Short press
Short
press
Short
press
Short press
Short press
Or
Or
Long press for 2s
Long press
for 2s
Long press
for 2s
Long press
for 2s
Long press
for 2s
Long press
for 2s
Long press for 2s
Long press
for 2s
Long press
for 2s
Short press short press to
select"Leading"
or "Lagging"
Long press
for 2s
Short press to
select 8~9
Short press to
select 0~2
Short press to
select 0~9
Short press to
select 0~9
Short press to
select 0~9
Wait
Wait
Wait
8.2.1 Inverter Parameter Introduction
Parameters Description
Normal
Home page. Indicates the real-time power of the inverter. Long press for 2s
to check the current safety code.
E-Today Check the generated power of the system for that day.
E-Total Check the total generated power of the system.
Vpv Check the DC input voltage of the inverter.
Ipv Check the DC input current of the inverter.
Vac Check the voltage of the utility grid.
Iac Check the AC output current of the inverter.
Fac Check the frequency of the utility grid.
Error History Check historical error message records of the inverter.
Model
Indicates the specic inverter model. Long press for 2s to set the safety
code. Set the safety country in compliance with the local grid standards and
application scenario of the inverter.