EasyManuals Logo
Home>Grant>Data Loggers>2020 Series

Grant 2020 Series User Manual

Grant 2020 Series
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
18108 Version 17 SQ2020/40
Page 21
www.grantinstruments.com
9. Specifications
ANALOGUE INPUTS
Basic accuracy (5-45°C): ..............................................± (0.05% readings + 0.025% range)
Common mode rejection: ...........................................................................................100dB
Input impedance: ...................................................................................................> 1MOHM
Linearity: ..................................................................................................................0.0015%
Series mode line rejection:...........................................................................50/60Hz 100dB
EM field and Conducted RF effect: ………………….………………….…...………….< 1%
DIGITAL INPUTS
Zero input voltage....................................................................... 0 to 0.5V (or shorted input)
One input voltage..................................................................2.7 to 5V (or open circuit input)
Input protection......................................will turn on below about -0.5V and above about 6V
ANALOGUE-DIGITAL CONVERSION
Type: ....................................................................................................................Sigma-Delta
Resolution: .....................................................................................................................24bit
Sampling rate: ..................................................................Up to 20/100 readings per second
Note: 100Hz Mode not available on 1F8 models
ALARM OUTPUTS.......................................................................4 x open drain FET (18V 0.1A Max)
SENSOR POWER SUPPLY..............................Regulated 5 VDC (50mA) or supply voltage (100mA)
TIME AND DATE...........................................................................................In built clock in 3 formats
SCALING DATA.......................................................Displays readings in preferred engineering units
MEMORY
Internal: ...........................................................................128 Mb (Up to 14,400,000 readings)
External: ...........................................................Up to 1Gb removable MMC/SD memory card
RESOLUTION.................................................................................................Up to 6 significant digits
PROGRAMMING/LOGGER SET-UP................................SquirrelView or SquirrelView Plus software
COMMUNICATION.......................................................USB 1.1 and 2.0 / RS232 / Ethernet (not 1F8)
Internal option: ……………………………………………...……………………………...Wi-fi
External options: ......................................................................GSM, Ethernet and wireless
POWER SUPPLY
Internal: ..........................................................................................6*x AA Alkaline batteries
External: .........................................10-18VDC, reverse polarity and over-voltage protected
This effect may be larger at 288kHz, re-orientate the input cables or add a suitable
axial ferrite bead close to the logger input if required.
* Maximum operating temperature for supplied alkaline batteries is 50°C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grant 2020 Series and is the answer not in the manual?

Grant 2020 Series Specifications

General IconGeneral
BrandGrant
Model2020 Series
CategoryData Loggers
LanguageEnglish

Related product manuals