EasyManuals Logo
Home>Grant>Data Loggers>Squirrel SQ2010 SERIES

Grant Squirrel SQ2010 SERIES User Manual

Grant Squirrel SQ2010 SERIES
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
SQ2010 28507 Version 6
Page 18
EN
9. Specifications
ANALOGUE INPUTS
Basic accuracy (5-45°C): .................................................± (0.10% readings + 0.1% range)
Common mode rejection: ...........................................................................................100dB
Input impedance: ...................................................................................................> 1MOHM
Linearity: ..................................................................................................................0.0015%
Series mode line rejection:...........................................................................50/60Hz 100dB
EM field and Conducted RF effect: ………………….………………….……...………….< 1%
DIGITAL INPUTS
Zero input voltage....................................................................... 0 to 0.5V (or shorted input)
One input voltage..................................................................2.7 to 5V (or open circuit input)
Input protection......................................will turn on below about -0.5V and above about 6V
ANALOGUE-DIGITAL CONVERSION
Type: ....................................................................................................................Sigma-Delta
Resolution: ......................................................................................................................24bit
Sampling rate: .........................................................................Up to 10 readings per second
ALARM OUTPUTS.......................................................................2 x open drain FET (18V 0.1A Max)
SENSOR POWER SUPPLY..............................Regulated 5 VDC (50mA) or supply voltage (100mA)
TIME AND DATE...........................................................................................In built clock in 3 formats
SCALING DATA.......................................................Displays readings in preferred engineering units
MEMORY............................................................................Internal: 16Mb (Up to 1,800,000 readings)
RESOLUTION.................................................................................................Up to 6 significant digits
PROGRAMMING/LOGGER SET-UP..................... ..........SquirrelView or SquirrelView Plus software
COMMUNICATION
Internal: .................................................................................................RS232 & USB 1.1/2.0
External options: ........................................................GSM, Ethernet and Wireless Ethernet
POWER SUPPLY
Internal:...............................................................................................2 x C Alkaline batteries*
External: ............................................8-28V DC Reverse polarity and over-voltage protected
* Maximum operating temperature for supplied alkaline batteries is 50°C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grant Squirrel SQ2010 SERIES and is the answer not in the manual?

Grant Squirrel SQ2010 SERIES Specifications

General IconGeneral
BrandGrant
ModelSquirrel SQ2010 SERIES
CategoryData Loggers
LanguageEnglish