18 - 24
GR-18_3D_jh_V1
Multicopter Yaw settings
Yaw P - Factor
Default setting: +45
The P factor is responsible for the harder snap to yaw. Higher
values result in a faster stop. At too high P-values the copter
starts to “swing”. In such cases, the value must be reduced
again.
Yaw I - Factor
Default setting: +15
The I-factor ensures constant rotations. Start with low values
and only increase them until the rotations are constant. Too high
value cause an oscillation when you stop and possibly the
motors can run higher. This can lead to an undesirable rise.
Yaw D - Factor
Default setting: MIN
The D-factor affects the stopping behavior in yaw. In most Cop-
ters a hard D action is necessary. The D component must be
set as low as possible, since it affects the whole system.
Multicopter Yaw<v>
>Yaw P 40
Yaw I 20
Yaw D 20