16
POWER AND WIRING INSTALLATION
Installing Wired Tether Controller to Ceiling Cassette
1. Open decorative grille and locate 4 pin connector for wired controller on Ceiling Cassette
main body
2. Route wired controller wires to 4-pin connector and connect Tether Controller to ceiling
cassette.
NOTE:
Use the supplied cable, with OEM plugs on either end. Do not cut or splice.
Conceal any excess cable.
1. Replace decorative grille being careful not to pinch wires.
2. Remove back plate from Wired Controller.
Outdoor Unit
Indoor Unit
Indoor Unit
Disconnect Switch
Wires
Outdoor Unit
Local codes may require a disconnect switch within sight of the indoor unit. Use a DFS Disconnect
Switch Accessory Kit (Part No: DFS-SWITCH-A) to break interconnecting wires going to the N(1),
2, 3, terminals on the indoor unit, as shown in the wiring diagram below:
Indoor Disconnect Switch (Optional)
Red
White
Black
Green