EasyManuals Logo

Gree GGD18L User Manual

Gree GGD18L
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Error Codes
Unit's Malfunction Codes
No.
Malfunction
Name
Display
Code
Unit's
Condition
Possible Causes
Display
Window
1
Ambient
Temperature
Sensor
Malfunction
F1
Compressor
and fan
motor stop.
Buttons are
invalid.
Ambient temperature sensor is
loosen or is poorly connected
with the terminal of display board.
Some element of display board
may have been put upside down
and cause short circuit.
Ambient temperature sensor is
damaged
.
Display board is damaged.
2
Tube
Temperature
Sensor
Malfunction
F2
Temperature sensor on the
evaporator is loosen or is poorly
connected with the terminal of
display board.
Some element of display board
may have been put upside down
and cause short circuit.
Temperature sensor on the eva-
porator is damaged.
Display board is damaged.
3
Humidity
Sensor
Malfunction
L1
Humidity sensor is short-circuited.
Humidity sensor is damaged.
Display board is damaged.
16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GGD18L and is the answer not in the manual?

Gree GGD18L Specifications

General IconGeneral
BrandGree
ModelGGD18L
CategoryDehumidifier
LanguageEnglish

Related product manuals