DC Inverter U-match Series Duct Type Unit
Indoor Unit Accessories
No. Name Appearance Q'ty Usage
12
Removal-Proof
Screw Nut
or Ordinary Nut+
Ta m pe rp ro o f
or
+
1
To p re ve n t th e re m ov a l of
the liquid pipe connecting
nut(Refer to the fittings
included in delivery)
13
Self-tapping
screw
4
To f ix t h e hanger(Only for
GUD160PHS/B-S and
1 Drain Plug
0 or 3
To p lu g th e u n us e d d r ai n
2
Drainage
or
1
To c on ne c t wi t h t h e ha r d
3 Rubber Ring
0 or 2
Used for threading
power cord or
4 Sealing Pad
0 or 1
Used for threading the
5 Fastener
0 or 3
To fasten the Rubber
Ring and the Sealing
6 Cable Tie
0 or 2
To fasten the power cord
3 Installation
3.1 Installation Preparation
3.1.1 Notice on Installation
(1) Notice on Refrigerant Concentration before Installation.
This air conditioner uses R32 refrigerant. The construction area for installation,
operation and storage of the air conditioner must be larger than the minimum
construction area. The minimum area for installation is determined by: