19
Installation Manual
7.1.4 Earthing Requirements
1
.Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed.
2.The yellow-green wire in air conditioner is the earthing wire which can not be used
for other purposes. Improper earthing may cause electric shock.
3.The earth resistance should accord to the national criterion.
4.The power must have reliable earthing terminal. Please do not connect the earthing wire with the following:
ķ
Water pipe
ĸ
Gas pipe
Ĺ
Contamination pipe
ĺ
Other place that professional personnel consider is unreliable
5. The model and rated values of fuses should accord with the silk print on fuse cover or relate d PCB.
7.2 Installation Drawing
Space to the ceiling
Space to the wall
Space to the wall
Air outlet side
Space to the floor
Above
Above
15cm Above
15cm Above
Above
The dimensions of the space necessary for proper
installation of the unit includ e the minimum
permissible distances to adjacent parts.
15cm
300cm
250cm