2.2 Operation Characteristic Curve
Cooling Heating
0 10 20 30 40 50 60 70 90 0 10 20 30 40 50 60 70 80 90 100 120110
80
11
10
9
8
7
6
5
4
3
2
1
0
11
10
9
8
7
6
5
4
3
2
1
0
220V
230V
240V
220V
230V
240V
Current (A)
Current (A)
Conditions
Indoor:DB27°C/WB19°C
Outdoor:DB35°C/WB24°C
Indoor air flow:Super High
Pipe length:5m
Conditions
Indoor:DB20°C/WB15°C
Outdoor:DB7°C/WB6°C
Indoor air flow:Super High
Pipe length:5m
Compressor speed (rps) Compressor speed (rps)
2.3 Capacity Variation Ratio According to Temperature
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
Capacity ratio(%)
Outdoor temp. (°C)
-20 -15 -10 -5 0 5 10
110
120
130
100
90
80
70
60
50
40
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:High
Pipe length:5m
Conditions
Indoor:DB27°C/WB19°C
Indoor air flow:High
Pipe length:5m
Condition
Indoor:DB20°C
/WB15°C
Indoor air flow:
High
Pipe length:5m
–15 –10 –5 5
110
100
90
80
70
60
50
40
0710
Conditions
Indoor:DB20°C/WB15°C
Indoor air flow:Super High
Pipe length:5m
Outdoor temp.(°C)
Cooling
+HDWLQJRSHUDWLRQDPELHQWWHPSHUDWXUHUDQJHLV&a&
+HDWLQJRSHUDWLRQDPELHQWWHPSHUDWXUHUDQJHLV&a&
Cooling
Heating
Heating