15
Operation Data
Notes:
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U-Bend.
(2) Length of connecting tubing = 24.6 .
(3) P = Pressure PSI
T1 = Inlet and Outlet Temperature for Evaporator
T2 = Inlet and Outlet Temperature for Condenser
Product Introduction
Temperature Condition (
O
F)
Model
Pressure
(PSI)
Heat Exchanger
Pipe Temperature
Indoor Fan
Mode
Outdoor Fan
Mode
Compressor
Speed
(rps)
Indoor Outdoor T1 (
O
F) T2 (
O
F)
80.6/66.6 95/75.2
9K 135 57.2 98.6 Turbo High 46
12K 152 59 98.6 Turbo High 70
18/24K 131-160
46.4-51.8 to
51.6-57.2
167-181.4 to
98.6-118.4 Turbo High 75
Cooling
Temperature Condition (
O
F)
Model
Pressure
(PSI)
Heat Exchanger
Pipe Temperature
Indoor Fan
Mode
Outdoor Fan
Mode
Compressor
Speed
(rps)
Indoor Outdoor T1 (
O
F) T2 (
O
F)
70/60 47/43
9K 401 113 41 Turbo High 56
12K 308 107.6 41 Turbo High 73
68/59 44.6/42.8 18/24K 319-348
167-181.4
98.6-113
33.8-37.4 to
35.6-42.8
Turbo High 75
Heating