Specifi cations
17
2.3 Capacity Variation Ratio According to Temperature
NOTES :
(1) T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure of air pipe connecting indoor and outdoor units(on the side of gas pipe)
(2) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(
3
)
Connectin
g
pipin
g
condition : 5 m
Cool i n t a e H gi n g
3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 3 –1 5
–10
5 0 5 7 10
4 0 4 1 42
100
105
95
90
85
80
75
70
65
60
55
50
Outdoor tem p . (˚C)
) %
(
o i t a r y t i c a p a C
110
100
90
80
70
60
50
40
Outdoor tem p . (˚C)
) % ( o i t a r y t i c a p a C
Conditions
Indoor:DB21.1
o
C /WB15.6
o
C
Indoor air flow:Turbo
Pipe length:5m
Conditions
Indoor:DB26.7
o
C /WB19.4
o
C
Indoor air flow:Turbo
Pipe length:5m
Cooling
Heating
Standard
pressure
Indoor Outdoor
P (MPa)
T1 (°C) T2 (°C)
18K 0.9 to 1.1 12 to 14 70 to 42 High High 62
24K 0.8 to 1.0 10 to 12 70 to 40 High High 78
Outdoor fan
mode
Compressor
Frequency
(Hz)
26.7/19.4 35/–
(°C)
Model
name
temp.
Indoor fan
mode
Standard
pressure
Indoor Outdoor
P (MPa)
T1 (°C) T2 (°C)
18K 2.2 to 2.4 70 to 37 2 to 4 High High 62
24K 2.5 to 2.7 70 to 37 0 to 3 High High 80
Outdoor fan
mode
21.1/
8/6.11
Temperature condition
Temperature condition
(°C)
Model
name
Heat exchanger pipe
Heat exchanger pipe
temp.
Indoor fan
mode
Compressor
Frequency
(Hz)
2.4 Operation Data