EasyManuals Logo
Home>Gree>Air Conditioner>GWH18RC-K3DNA3G/I

Gree GWH18RC-K3DNA3G/I User Manual

Gree GWH18RC-K3DNA3G/I
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
59
Installation and Maintenance
Service Manual
(3)
Malfunction of Overload Protection of Compressor (H3) and Discharge High-temperature Protection of Compressor (E4)
Main check point:
Whether the electronic expansion valve is connected well and whether it’s damaged?
Whether the refrigerant is leaking?
Whether the overload protector is damaged?
Check ow chart:
Start
Whether the overload protector is
connected?
Replace overload
protector
Connect wire
correctly according
to circuit diagram
Measure the resistance between both
ends of overload protector under
ambient temperature. Whether the
resistance <1KΩ?
Whether wire connection wire electronic
expansion valve is in good condition?
Check the coil of electronic
expansion valve. If it’s
damaged, please replace it.
Is malfunction eliminated?
If the refrigerant is leaking,
please add refrigerant
according to Service Manual.
Is malfunction eliminated?
Replace main board of
outdoor unit
End
Yes
Yes
Yes
Yes
No
No
No
No
Yes
No
Remark:
Detection method for electronic expansion valve: There are 5 wires for the coil of electronic expansion valve and one of them are
common port (the left or the right wire) .The resistance for other terminals are all most the same (about 100Ω). You can measure
those resistance values to judge whether the electronic expansion valve is damaged or not.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH18RC-K3DNA3G/I and is the answer not in the manual?

Gree GWH18RC-K3DNA3G/I Specifications

General IconGeneral
BrandGree
ModelGWH18RC-K3DNA3G/I
CategoryAir Conditioner
LanguageEnglish

Related product manuals