7URXEOHVKRRWLQJ
3RZHUIDFWRUFRUUHFWRU3)&IDXOWDIDXOWRIRXWGRRUXQLW$3KHUHLQDIWHUUHIHUVWRWKHFRQWUROERDUGRIWKH
RXWGRRUXQLW
0DLQO\GHWHFW
Ɣ&KHFNLIWKHUHDFWRU/RIWKHRXWGRRUXQLWDQGWKH3)&FDSDFLWRUDUHEURNHQ
)DXOWGLDJQRVLVSURFHVV
Y
Y
N
N
N
N
N
N
Y
Y
Y
Start
Check wiring of the
reactor (L) of the
outdoor unit and the
PFC capacitor
Whether there is any
damage or
short-circuit?
Replace it as per the
wiring diagram and
reconnect the wires
If the fault is eliminated?
Remove the PFC capacitor
and measure resistance
between the two terminals.
Is the resistance around zero?
The capacitor is
short circuited and
the capacitor
should be repla-
ced
Restart the unit
If the fault is eliminated?
Disconnect the terminals for the
reactor and measure the resistance
between the two terminals of the
reactor by an ohm gauge
Whether there is any damage
or short-circuit?
Replace the reactor
Restart the unit
If the fault is eliminated?
Replace the control
panel AP1
End
Y

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH18UC-K3DNA1A/I and is the answer not in the manual?

Gree GWH18UC-K3DNA1A/I Specifications

General IconGeneral
BrandGree
ModelGWH18UC-K3DNA1A/I
CategoryAir Conditioner
LanguageEnglish

Related product manuals