Artful
Buzzer
If air conditioner energized or the unit received the effective information sent by the wireless remote control.
The buzzer will beep.
Sleep Function
Under cooling or dehumidify mode, the preset temperature will automatically rise by 1 one hour after setting of sleep
program and rise by 2 after 2 hours.
Under heating mode, the preset temperature will automatically decrease by 1 one hour after setting of sleep program
and decrease by another 1 after 2 hours.
Other Control
Timer function
Ordinary Timer setting
Timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer
interval is 0.5hr, setting range is 0.5-24hrs.
Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer
interval is 0.5hr, setting range is 0.5-24hrs.
Timer setting for hour:
Timer on: If system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, when timer on has arrived,
the system will run at pressetting mode.
Timer off: If system is off to set up the timer off, when to set up timer off, the unit will standby, when unit is on, to set up timer off, when
the timer off arrived, the system will stop to work.
Timer setting change:
When system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run
at last setting status.
When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start
to work.
Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop.
Auto key
If one press of this key, the unit will run under AUTO mode and the indoor fan will run at AUTO SPEED. The swing motor is started when
the indoor fan is working. Press this key again to stop the unit.
If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temp. resumes to normal,
the outdoor fan will be restarted.
Noise Sliencing Protection
If the unit is stopped by pressing ON/OFF, or mode switching, the reversal valve will be stopped after 2-minute lag.
Over current protection
It is the same as that under cooling mode (only indoor fan will run at low speed for 60 seconds before it is stopped).
Fan mode
Under FAN mode, only the indoor fan runs at preset speed, the compressor,outdoor fan and 4-way valve are stop.
Under this mode,the temperature can be set within a range from 16 to 30 .
Auto Mode
Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temp.
Protection function is the same as that under each modes.There is 30s delay for mode switch.
There are Ordinary Timer setting and Timer setting for hour function, by different kind of remote control to select the timer function.
Tpreset
Tpreset
Tpreset
Setting temp. Tpreset
1hr.
2hrs.
2hrs. above