221
Service Manual
F:Inspection
Check the quality of expanding port. If there is any blemish, expand the
port again according to the steps above.
The length is equal
Improper expanding
leaning
damaged
surface
crack uneven
thicknes
s
Smooth surface
Downwards
Pipe
Shaper
Union pipe
Pipe
Expander
Hard
mold
Pipe
Pipe
Pipe cutter
Leaning Uneven Burr
Improper pipe expanding is the main cause of refrigerant leakage.Please
expand the pipe according to the following steps:
A:Cut the pip
Conrm the pipe length according to the distance of indoor unit and outdoor unit.
Cut the required pipe with pipe cutter.
B:Remove the burrs
Remove the burrs with shaper and prevent the burrs from getting into the pipe.
C:Put on suitable insulating pipe
D:Put on the union nut
Remove the union nut on the indoor connection pipe and outdoor valve; install
the union nut on the pipe.
E:Expand the port
Expand the port with expander.
"A" is different according to the diameter, please refer to the sheet below:
Outer
diameter(inch)
A(inch)
Max Min
Ф0.24 - 0.25 (1/4") 0.05 0.03
Ф0.37 (3/8") 0.06 0.04
Ф0.47 - 0.50 (1/2") 0.07 0.04
Ф0.63 - 0.625 (5/8") 0.09 0.09
Appendix 3: Pipe Expanding Method
Note:
Note:
113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree LIVV18HP230V1AO and is the answer not in the manual?

Gree LIVV18HP230V1AO Specifications

General IconGeneral
BrandGree
ModelLIVV18HP230V1AO
CategoryAir Conditioner
LanguageEnglish

Related product manuals