Operation
Air Flow Direction Adjustment
Basic Operation
Remote controller
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
It is impossible to change the settings of temp. and fan spee
d,It
is also not possible to operate in timer or dry mode.
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease . rapidly Select a desired
temperature.
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
/
Display
circulated
changes as
LOW
MED HI
AUTO
Remote
Controller
Note
In DRY mode , when room temperature becomes lower
th
an temp.setting+2
o
C, unit will run intermittently at
LOW speed regardless of FAN setting.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in
FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
Operation
Mode
DRY
COOL
FAN
Test operation:
Test operation switch is the same as emergency switch.
Service personnel
Continue to press the test operation
switch for more than 5 seconds.After
you hear the "Pi" sound twice,release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Pi Pi
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 23
o
C 26
o
C AUTO COOL
No
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
at air outlet if all vertical louvers are adjusted to left or right.
It is advisable not to keep horizontal flap at downward position
for a long time in COOL or DRY mode ,otherwise, condensate
water might occur.
1.Status display of air flow
2.Left and right air flow adjustment
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
For each press of button, remote controller
displays as follows :
remote controller:
Vertical flap
Pos.1
(Auto
swing)
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
2
Press button to enter additional options, when
enter to FAN function.
1. Start unit
Press ON/OFF
Start unit
2. Select operation mode
COOL button:Cooling mode
DRY button: Dehumidify
mode
3. Select temp. setting
In COOL mode,the AC unit will emit Cool air according
to the remote setting on the temperature display The
Setting temperature is adjustable
Pi
Note: In some model: The remote has the button , But
the AC doesn’t have the left and right air flow auto adjustment
function, this condition change the direction of ivertical blades
manually.
(the function only applicable for certain models)
Cautions:
MODE

Questions and Answers:

Haier HSU-10TSV13-SC Specifications

General IconGeneral
TechnologyInverter
Outdoor Noise Level50 dB
Compressor TypeRotary
Power Supply Frequency50 Hz
Noise Level (Outdoor)50 dB
Net Weight (Indoor Unit)9 kg
TypeSplit
Power Supply220-240V
RefrigerantR22
Refrigerant TypeR22