Indoor unit
Make a hole of B mm / inches
in diameter, slightly descending
to outside the wall.
ƽ
Install piping hole cover and seal it off with putty after installation
ƽ
When the mounting plate is first fixed
1. Carry out, based on the wall studs or lintels, a
to be fixed against the wall, then temporarily fasten the plate with one nail.
2. Ensure
the proper level of the plate, by
hanging a thread with a
weight from the central top of the plate, then fasten the plate.
3. Find the wall hole location A using a measuring tape
FittingoftheMountingPlateand
Positioning of the wall Hole
Lid for right
piping
Lid for under piping pipe
Fix with adhesive tape
Lid for left piping
Indoor/outdoorelectriccableanddrainhosemustbeboundwithrefrigerant
ƽ
piping with adhesive.
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping direction and
ƽ
then bend the pipe according to theposition of wall hole. When bending, be
careful not to crush
pipes.
Make sure that the wires connecting the indoor and outdoor units are not covered
by the refrigeration piping insulation and are long enough to connect to the terminal
block on the indoor unit.
ƽ
proper leveling for the plate
Making a Hole on the Wall and Fitting the Piping Hole Cover
Drawing of pipe
Installation of the Indoor Unit
[Rearpiping ]
Drawpipesandthedrainhose,thenfastenthemwiththeadhesivetape
ƽ
[Left
·
Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping.
ƽ
In case of left-rear piping, bend the pipes according to the piping direction to
ƽ
the mark of hole for left-rear piping which is marked on insulation materials.
1. Insert the drain hose into the carity of heat insulation materials of indoor unit.
2.Inserttheindoor/outdoorelectriccablefrombackside of indoor
unit, and pull it
out on the front side, then connect them.
3.Coattheflaringsealfacewithrefrigerantoilandconnect pipes.
Cover the tubing connection with insulation materials closely, and with adhesive
tape.
Fixingtheindoorunitbody
Hang the unit body onto the upper notches of the
ƽ
mounting plate. Move the body from side to side to verify
its
secure fixing.
Inordertofixthebodyontothemountingplate,holdup
ƽ
thebodyfromtheundersideandthenputitdown
perpendicularly.
mounting plate
When you unload the indoor unit,please use
lift the bottom of the body outward
slightly and lift the unit until
it leaves the mounting plate.
agraffe
mounting plate
Unloading of indoor unit body
ƽ
your hand to raise the body , then
Remote controller (1)
AAA dry battery (2)
Mounting plate (1)
Drain hose (1)
Ø4X25 Screw
(4)
Plastic cap (4)
Drain-elbow (1)
Cushion (4)
Pipe supporting plate (1)
Accessory parts
NOTE˖The thickness of the pipe must be 0.8mm(1/16”) at least.
Selectionofpipe
2
Insulation
material
Drain hose
Piping
Pipe supporting
plate
Indoor/outdoor electric cable
Indoor side
Outdoor side
ØBmm
Wall hole
Thickness of wall
(Section of wall hole)
Piping hole pipe
G
Model Liquid pipe (Ø)
Gas pipe (Ø)
6.35mm (1/4")
6.35mm (1/4")
6.35mm (1/4")
9.52mm (3/8")
9.52mm (3/8")
9.52mm (3/8")
12.7mm (1/2")
15.88mm (5/8")
A = 145mm
30mm
A = 145mm
B = Ø 60mm
30mm
B = Ø 60mm
B= 70mm
35mm
A=150mm
A=150mm
mm
35mm
12k
18k
24k
HSU09VHG(DB)-W
HSU12VHG(DB)-W
HSU18VHG(DB)-W
HSU24VHG(DB)-W
09k
09k/12k : B= 60mm(2 3/8 inches)
18k/24k : B=70mm(2 3/4 inches)
(5 11/16 inches)
(1 1/6
inches
)
(1 1/6
inches
)
(5 11/16
inches
)
(1 3/8
inches
)
(5 7/8 inches)
(2 3/4
inches
)
(1 3/8
inches
)
(2 3/4
inches
)
(5 7/8 inches)
(2 3/8 inches)
(2 3/8 inches)
Pitch downward for drainage

Other manuals for Haier HSU09VHG(DB)-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HSU09VHG(DB)-W and is the answer not in the manual?

Haier HSU09VHG(DB)-W Specifications

General IconGeneral
BrandHaier
ModelHSU09VHG(DB)-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals