84
2.9 Branch pipe dimensions
3-pipe systerm
Suction gas branch pipe HP gas branch pipe Liquid branch pipe Suction gas manifold pipe HP gas manifold pipe
Liquid
manifold pipe
FQG-R335A
OD22.22
ID22.4
ID19.3
ID16.1
OD19.05
384
ID16.1
ID12.9
ID12.9
OD25.4
ID22.4
ID19.3
ID16.1
OD22.22
ID22.4
ID19.3
ID16.1
OD19.05
384
ID16.1
ID12.9
ID12.9
OD25.4
ID22.4
ID19.3
ID16.1
ID6.5
ID9.7
OD9.53
238
OD9.53
ID9.7
ID6.5
Ø12.7
ID9.7
OD12.7
100
ID9.7
104
OD15.88
ID12.9
ID9.7
104
OD15.88
ID12.9
ID9.7
OD12.7
100
ID9.7
104
OD15.88
ID12.9
ID9.7
104
OD15.88
ID12.9
ID9.7
55
OD6.35
ID9.7
55
OD6.35
ID9.7
FQG-R506A
ID28.8
ID25.6
OD22.2
OD25.4
323
OD22.22
ID22.4
ID19.3
ID16.1
ID12.9
ID25.6
ID28.8
ID28.8
ID25.6
OD22.2
OD25.4
323
OD22.22
ID22.4
ID19.3
ID16.1
ID12.9
ID25.6
ID28.8
ID9.7
ID12.9
OD9.53
ID6.5
ID9.7
OD9.53
ID12.9
OD12.7
ID12.9
238
OD28.58
ID25.6
ID22.4
ID19.3
ID16.1
ID12.9
180
OD12.7
100
ID9.7
OD28.58
ID25.6
ID22.4
ID19.3
ID16.1
ID12.9
180
OD12.7
100
ID9.7
55
OD6.35
ID9.7
FQG-R730A
ID28.8
ID25.6
OD22.2
OD25.4
323
OD22.22
ID22.4
ID19.3
ID16.1
ID12.9
ID25.6
ID28.8
ID28.8
ID25.6
OD22.2
OD25.4
323
OD22.22
ID22.4
ID19.3
ID16.1
ID12.9
ID25.6
ID28.8
ID9.7
ID12.9
ID16.1
OD19.05
OD25.4
ID16.1
388
OD19.05
ID16.1
ID12.9
ID9.7
ID6.5
OD28.58
ID25.6
ID22.4
ID19.3
ID16.1
ID12.9
180
OD12.7
100
ID9.7
OD28.58
ID25.6
ID22.4
ID19.3
ID16.1
ID12.9
180
OD12.7
100
ID9.7
55
OD6.35
ID9.7
FQG-R1350A
ID38.3
ID32
OD31.75
366
OD28.6
ID28.8
OD31.75
ID32
ID38.3
ID38.3
ID32
OD31.75
366
OD28.6
ID28.8
OD31.75
ID32
ID38.3
ID9.7
OD19.05
405
ID16.1
ID12.9
ID9.7
ID6.5
ID12.9
ID16.1
ID19.3
ID22.4
OD22.22
OD25.4
ID22.4
ID19.3
OD28.58
ID25.6
ID22.4
ID19.3
ID16.1
ID12.9
180
Ø34.9
ID32
ID28.8
ID25.6
ID22.4
180
OD22.22
ID19.3
ID16.1
ID12.9
138
OD12.7
100
ID9.7
ID35.1
OD38.1
49
OD28.58
ID25.6
ID22.4
ID19.3
ID16.1
ID12.9
180
Ø34.9
ID32
ID28.8
ID25.6
ID22.4
180
OD22.22
ID19.3
ID16.1
ID12.9
138
OD12.7
100
ID9.7
ID35.1
OD38.1
49
55
OD6.35
ID9.7
FQG-R335A FQG-R506A FQG-R730A FQG-R1350A
Note: Cut off the pipe from its middle when using.
Unit: mm, ID: inner diameter, OD: outer diameter