Harman® • Absolute63 Owner’s Manual_R6 • 2016 -___ • 11/1725
3-90-999000c
ISSUES SOLUTIONS
Stove does not feed
• No fuel in hopper.
• Fireboxdraftmaybetoolowforsensingswitchinfeeder
circuit to operate. Check for closed doors, loose or missing
gasket on doors or hopper lid.
• Restriction in the hopper or feeder. Remove all fuel and
examine.Cleartheobstruction.
• Feed motor has failed.
Partially burned pellets
• Feed rate too high.
• Poorairtofuelmixture.(Checkburnpotclean-outcover
and air intake).
• Burn pot may need to be cleaned.
• Combination of all the above.
Smoke smell
Sealtheventpipejointsandconnectiontostovewithsilicone.
Theexhaustventistheonlypartofthesystemthatisunder
positive pressure.
Fire has gone out
• No fuel in hopper.
• Draftistoolow,blockedue.
• Somethingisrestrictingfuelow.
• Hopper lid not closed properly.
• Feed motor or combustion fan has failed.
Smoke is visible coming out of vent
• Air-fuelratioistoorich.
-Feedratetoohigh.
-Drafttoolowcausedbyagasketleak.
Low heat output
• Feed rate too low.
• Draft too low because of gasket leak.
• Poor quality or damp pellets.
• Combination of 1 and 2.
Stove does not ignite but igniter is operating correctly
• Burnpothasexcessashlocatedaroundigniterandbracket.
• Burpot grate holes are blocked or partially block.
E. Troubleshooting