B. Fire Characteristics
A properly adjusted re has an active ame pattern.
C. Feed Rate Adjustment Instructions
The feed adjustment control is factory set at #4, and should
be adequate for most fuels.
However, if the flame height is too high or too low, you will
need to adjust the feed rate. Wait until the appliance has been
burning for 15 minutes before making your adjustments and
a
llow 15 minutes for feed adjustment to take effect.
A. Starting Your First Fire
1. A room sensor is required for proper operation of this
appliance in “Room Temp” mode. At this time, ll the
hopper with pellets, ensure the control is set to “OFF”.
Figure 4.2. Plug the power cord into a properly grounded,
nearby outlet.
2. Once power is present, the unit it will run through a quick
diagnostics test to insure the control is operating properly.
This is normal.
3. For your rst re it may be necessary to purge the auger
system by putting the feed adjuster knob to “Test” prior
to starting the unit. Figure 4.3. This insures that plenty of
fuel enters the burn pot for proper ignition.
4. Flip toggle switch to desired mode “auto or manual”. Figure
4.4. Set feed adjuster knob to desired setting and turn
mode dial to “Room Temp” or “Stove Temp” Figure 4.5.
Note: Feed rate of #4 is a good starting point. Adjustments
may need to be made depending on fuel quality and/or
heat output desired.
5.
The fuel feed system and the igniter should
now
be on.
6. Once the appliance has ignited, let it burn for approximately
7-10 minutes. After this time, the igniter light should turn
off and the unit should begin to operate per the settings
at the control.
Figure 4.5
Figure 4.2 Figure 4.3
Figure 4.4
4
Operating Instructions
Odors and vapors released during initial operation.
• Curing of high temperature paint.
• Open windows for air circulation.
Odors may be irritating to sensitive individuals.
CAUTION