8
3-90-00674R28_12/13
ESP Control
3 Blinks:IndicatesthattheESP(ExhaustSensingProbe)
hasfailed,hasabrokenconnection,orhasgoneoutofrange
toomanytimes.Thisrequiresamanualreset*.
4 Blinks: Can occur only in Room Temp Mode and
indicatesRoomSensingProbe failed ornotinstalled.If a
RoomSensingProbeistheninstalled,thestatuslightwill
automaticallyreset.
NOTE:Unitwillnotstartin"AUTO"withthisstatuserror.
5 Blinks (In Igniter Auto. Mode Only):Indicatesthattheunit
hasfailedtolightwithinthe36minutestartcycle.Toreset-
TurnModeSelectorto"OFF",thenturntoeithermodeagain.)
6 Blinks :Indicatesthatthecontrolhascalculatedpooror
incompletecombustionoccurringformorethan25minutes.
Asixblinkstatusmaybesetifthestoveisallowedtorunout
ofpellets.Toreset,turnmodeselectorto"OFF"thenback
ontothedesiredmode.Iftheunitwasnotoutofpellets,see
Troubleshootingsection,Page33,formoredetails.
* Manual reset-disconnectpowercordforafewseconds
andreconnect.IferrorstilloccurscallyourDealer.
Feed adjuster
Sets the maximum feed
rate
Test
Runs all motors at full
speed for one minute
to check operation.
Afterwards the control
will simulate a minimum
burn with the combustion
blower remaining on
low.
Distribution Blower
speed adjustment
range.
L = low
H = high
Variable speed
anywhere between L
and H; although as the
stove temp. goes up , so
does the L and H scale.
Temp dial
Allows you to adjust the room temperature
setting, in Room Temp Mode, using
the outer scale marked in degrees
Fahrenheit. It also allows you to adjust
the stove temperature setting, while in
Stove Temp Mode, using the inner scale
marked from 1 to 7.
Mode Selector
Allows you to choose between Room
Temp Mode, Stove Temp Mode, or OFF.
Also allows you to vary the distribution
blower speed by turning the knob to the
high or low side of each mode.
Power Light
Indicates power to the
control.
Indicates power to the
feed motor.
Indicates power to
combustion blower
Status Light
Will be lit in either stove
or room temp mode
when pointer is not
within off position band
except after normal shut
down. Blinks to indicate
errors listed below.
Indicates power to
distribution blower.
Dealer Diagnostic Port
For dealer maintenance only.
Requires special DDM monitor
supplied to Harman Dealers
exclusively.
Status light error messages:
Indicates igniter is on.
Igniter switch
Set to appropriate Start-
Up mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman Accentra Pellet Insert and is the answer not in the manual?