The Advance Pellet Stove is capable of manual operation. This also allows the opera-
tor to manually control operation during an emergency (i.e. igniter failure.) The unit can be
switched between "AUTO" and "MANUAL" at any time during operation.

        


This setting will produce a large viewing re without
a distribution blower operating.

Room Temperature Mode: This setting will produce
a room temperature of 70 degrees with the distribution
blower at medium speed.


The re will have to be lit with starting gel and a
match, or started automatically, see "Automatic Opera-
tion". Switch to "Manual" position after the ignition cycle
begins.
The difference between "AUTO" Room Tempera-
ture Mode and "Manual" Room Temperature Mode is
that the re will not go out as the room temperature goes
above the control board setting. The unit can only go to
low burn and will remain there until it runs out of fuel or
until more heat is needed and the feed rate increases.
Feed rate adjustments and dial settings are the same
as "AUTO" settings.



The advantage of this mode is to allow the operator
to have a large viewing re without blowing extra heat
into the room.
During operation, with the temperature dial set at
#3 or less, the distribution fan will not operate. A #3 on
the temperature dial and a #5 on the feed adjuster is
approximately 80% output. It is not necessary to operate
the distribution blower below this point. Therefore, there
can be a higher feed rate ( a larger viewing re) without
an excess of hot air blowing into the room.
An example of when to use the Manual Stove
Temperature Mode is if you want to watch a large re
and the room is already up to temperature. The Stove
Temperature Mode allows you to have a larger re and
a lower sound level, without the distribution blower.







Other manuals for Harman Advance Pellet Stove

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman Advance Pellet Stove and is the answer not in the manual?

Harman Advance Pellet Stove Specifications

General IconGeneral
BrandHarman
ModelAdvance Pellet Stove
CategoryPellet stove
LanguageEnglish

Related product manuals