Harman® • P42i Owner’s Manual • 2023 -___ • 03/2327 8742-900A
C. Loss of Power
Harman pellet burning appliances rely on a combustion
blowertoremoveexhaustfromtherebox.Apowerfailure
will cause the combustion blower to stop running, which
mayleadtoexhaustseepageintotheroom.Verticalrisein
the venting system can help create natural draft, which may
reducethelikelihoodofexhaustleakageintothehome.
Installationofalow-costuninterruptiblepowersupply(UPS)
or battery backup system can help ensure the units shuts
down without any minor smoke leakage into the home.
Harman recommends the installation of one of these two
systems for areas prone to power outages.
There is one Harman® approved UPS option for your
appliance:
Uninterruptible Power Supply UPSbatteryback-upsare
availableonlineoratcomputerando󰀩ceequipmentstores.
Your Harman® appliance with Rev E or later software
available beginning in November 2010 may be plugged
directlyintoaHarman®approvedUPS:
TrippLite model INTERNET750U is tested and
approved. Other brands or models may not be
compatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,
combustion blower only shut-down. Your appliance will
pulsetheblowereveryfewsecondstoclearexhaustuntil
thereisout. NOTE: The UPS provides safe shut-down
only. It is not intended for continued operation.
• A Inverter/Charger connects to a 12 volt deep cycle
battery that will run your appliance for up to eight (8)
hours.Itincludesatricklechargefeaturethatkeepsyour
battery charged when power is available. NOTE:Ifthe
power is out for longer than battery life, smoke leakage
may still occur unless your stove has been safely shut
down.
For an approved Inverter/Charger refer to www.
harmanstoves.com.
Yourappliancewillrecognizewhenpowerisrestored.What
happens depends on ESP temperature and whether it is
equipped with automatic ignition:
In “Automatic” Mode, units equipped with automatic
ignitionwillrespondtothesetpointandESPtemperature
and resume normal operation.
In “Idle” Mode, or for units without automatic ignition:
• If the ESP is cool, the appliance will remain shut
down.
• IfthereisoutandtheESPisstillwarm,thefeeder
mayrestart.Sincethereisout,theESPtemperature
willnotrise.Theunitwillthenshut-down,andmay
ashasix-blinkstatuserror.(SeeESPerrorcodes)
• If the re is still burning, it will resume normal
operation.
Contact your dealer if you have questions about UPS
compatibility with your appliance.
IMPORTANT! :UPSorBatteryBackupcannotpreventsmoke
leakage from an improperly maintained unit. Keep the venting
system clean and free from obstructions and maintain all
gaskets to keep an airtight seal.
Use only Harman
®
approved battery back-up devices.
Other products may not operate properly, can create
unsafe conditions or damage your appliance.
CAUTION
Always keep appliance doors and hopper lid closed
and latched during operation and during power
failures to minimize risk of smoke or burn-back.
D. Emergency Manual Ignition
Harman
®
pellet stoves and inserts should be lit using the
automatic ignition system. This is the safest and most
reliablewayforignitingtheunit.Intheeventtheautomatic
igniter is not functioning, the steps below may be followed
to manually light the stove or insert in the “Constant Burn”
mode. Manual lighting is for emergency purposes only,
and the igniter should be repaired or replaced as soon as
practical.
WARNING
Only use restarter commercially marketed for pellet
stoves and inserts, including wax coated wood chips,
pellet starter gel and pellet igniter blocks. Use of any
othertypeofrestarterisprohibited.
To avoid serious injury or death read and follow
manufacturer’swarningandinstructionsforuseofrestarter.
Useofrestarterisonlypermittedwhenperformingacold
start.
Never attempt to manually light a stove or insert that has
been operated recently and is not at room temperature.
If automatic ignition was attempted, be sure to give the
stoveorinsertatleast30minutesorlongertocooltoroom
temperature.
Besurethatthestoveorinsertisinthe“Igniter-Disabled”
mode of operation.
Once all the precautions have been taken, follow these
steps:
1.On the touch control, select the Burn Mode icon then
select “Constant Burn”.
2. ArrowbackandselecttheIgnitericonthenselect“Manual”
fortheignitionmethod.SelecttheHomeIcontogoback
totheMainMenu.
3.Fillburnpotwithpellets,onlyhalfway.(DoNotOverFill).
4. Add firestarter to pellets following manufacturer’s
instructions.
5.Lightpelletgelwithamatch,andclosethedoor,touch
theOn/O󰀨icononthehomescreen.Operationwillbegin
whentherereachesthepropertemperature.
WARNING

Other manuals for Harman P42i-TC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P42i-TC and is the answer not in the manual?

Harman P42i-TC Specifications

General IconGeneral
BrandHarman
ModelP42i-TC
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals