Harman® • P-Series Owner’s Manual_R1 • 03/1417 3-90-436168c
F. Manual Ignition (Continued)
TheP-SeriesPelletStoveiscapableofmanualoperation.
Thisalsoallowstheoperatortomanuallycontroloperation
duringanemergency(i.e.igniterfailure,whenusinga512H
batterybackup,orwhenusingcertaingenerators.)
Theunitcanbeswitchedbetween"AUTO"and"MANUAL"
atanytimeduringoperation.
Igniter Switch to "MANUAL"
Room Temperature Mode
Therewillhavetobelitwithstartinggelandamatch,or
started automatically, see "Automatic Operation". Turnto
"Manual"positiononcethestartcyclebegins.
Thedifferencebetween"AUTO"RoomTemperatureMode
and"Manual"RoomTemperatureModeisthattherewillnot
gooutastheroomtemperaturegoesabovethecontrolboard
setting.Theunitcanonlygotolowburnandwillremainthere
untilitrunsoutoffueloruntilmoreheatisneededandthe
feedrateincreases.Feedrateadjustmentsanddialsettings
arethesameas"AUTO"settings.
Igniter Switch to "MANUAL"
Constant burn Mode
Theadvantageofthismodeistoallowtheoperatortohave
alargeviewingrewithoutblowingextraheatintotheroom.
Duringoperation,withthetemperaturedialsetat#4orless,
thedistributionfanwillnotoperate.A#4onthetemperature
dialanda#4onthefeedlimitisapproximately80%output.
Itisnotnecessarytooperatethedistributionblowerbelow
this point. Therefore, there can be a higher feed rate (a
largerviewingre)withoutanexcessofhotairblowinginto
theroom.
AnexampleofwhentousetheManualConstantburnMode
isifyouwanttowatchalargereandtheroomisalreadyup
totemperature.TheConstantburnModeallowsyoutohave
alargerreandalowersoundlevel,withoutthedistribution
blower.
NOTE: During the use of this mode, if you keep increasing
the temperature dial setting to increase the re size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350
°
F, or 81% output.
NOTE: When starting the unit in the "AUTO" mode
and switching to "MANUAL", you may switch at any
time. Once an ignition cycle is started, it will continue
regardless of mode.
Room Temperature Mode: This setting will produce a room temperature
of 70 degrees with the distribution blower at medium speed.
Thissettingwillproducealargeviewingrewithoutadistribution
blower operating.
Manual Constant burn Mode