5
XXV Pellet Stove
Installing
Place the stove on a non-combustible oor
protector that extends a minimum of 6 inches
tothefront,2inchestothesidesandushwith
the rear of the hopper. Ash protection must also
be positioned under any horizontally run ue
pipe.Theminimumoorprotectormaterialis20
gaugesheetmetal.Otheroorprotectormateri-
als are ceramic tile, stone, brick, etc.
Place the stove away from combustible walls
at least as far as shown in Figures 2, 3 and 4.
Note that the clearances shown are minimum
for safety but do not leave much room for access
when cleaning or servicing. Please take this into
account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz
grounded receptacle. (A surge protector is recommended to
protect the circuit board.) If the voltage entering your home
is below 116 volts your stove may not work properly. Also be
sure that the polarity of the outlet that the stove is plugged
into is correct.
Priortoinstallingtheuepipe,connectadraftmeter.(The
draft meter must have a minimum range of 0-.5.)Record the
rstreading.Connectuepipetostoveandbesurealldoors
and windows in the home are closed. Record the second
draft reading_______. If the second reading is more than .05"
lowerthantherstreading,checkforpossiblerestrictionsor
the need for outside air (see page 8). For more information
on the draft test procedure, refer to Page 20.
Mobile Home Installation
When installing this unit in a mobile home several re-
quirements must be followed
(Reference HUD Regulation
#24CFR3280)
:
1.Theunitmustbeboltedtotheoor.Thiscanbedoneby
using clips (part # 2-0-677110) and 1/4" lag screws.
2. The unit must also be connected to outside air. See
page 8.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.
CAUTION: This appliance must be vented to the out-
side.
4" from
back of top
ueventto
wall
18"
Fig. 5: Optional Top Vent Pipe Clearances
Fig. 2
6.25"
6.25"
Installation
Fig. 3
12"
3"
Floor Protection must be 2 inches to each side, 6
inches to the front, and 0 inches to the back of the
stove. Floor Protector minimum: 32" wide x 32"
deep.
Fig. 4
0"
32" minimum
32 minimum
2" from
side of
stove to
combustible
surface
6" from
glass
6" from
pipe to wall
Mobile home regulations do not allow
installation in a room designated for
sleeping.
WARNING
CAUTION
THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.