This method provides excellent venting for nor-
mal operation and allows the stove to be installed
closest to the wall. Two inches from the wall is
safe; however, four inches allows better access to
remove the rear panel. The vertical portion of the
vent should be three to ve feet high. This vertical
section will help provide natural draft in the event of
a power failure.
Fig. 9
3 ft.
to combustibles
Fig. 10
12" min. wall to outlet
3 ft.
to combustibles
3 ft.
to combustibles
3 ft.
to combustibles
Fig. 11
This method also provides excellent venting for
normal operation but requires the stove to be in-
stalled farther from the wall. The vertical portion of
the vent should be three to ve feet high and at least
three inches from a combustible wall. This vertical
section will provide natural draft in the event of a
power failure.
If the stove is installed below grade be sure the
vent termination is at least 18" above grade. The
outlet must also be 1 foot from the house/building.
Note: Do not place joints within wall pass-
throughs.