XXV Pellet Stove

Place the stove on a non-combustible oor
protector that extends a minimum of 6 inches
to the front (152mm), 6 inches to the sides
(152mm) and ush with the rear of the hopper.
Front and side oor protection measurements
are made from the rebox or window opening.
Floor protection must also be positioned under
horizontal ue pipe. The minimum oor protec-
tor material is 20 gauge sheet metal. Other
oor protector materials are ceramic tile, stone,
brick, etc.
Place the stove away from combustible walls
at least as far as shown in Figures 2 and 3.
Note that the clearances shown are minimum
for safety but do not leave much room for access when
cleaning or servicing. Please take this into account when
placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect
the circuit board.) Also be sure that the polarity of the outlet
that the stove is plugged into is correct.
Prior to installing the ue pipe, connect a draft meter.
(The draft meter must have a minimum range of 0-.5.)
Record the rst reading. Connect ue pipe to stove and be
sure all doors and windows in the home are closed. Record
the second draft reading_______. If the second reading
is more than .05" lower than the rst reading, check for
possible restrictions or the need for outside air (see page
10). For more information on the draft test procedure, refer
to Page 17.

When installing this unit in a mobile home several re-
quirements must be followed
(Reference HUD Regulation
#24CFR3280)
:
1. The unit must be bolted to the oor. This can be done
by using clips (part # 2-00-677110B) and 1/4" lag screws.
2. The unit must also be connected to outside air. See
page 10.
3. Floor protection and clearances must be followed as
shown.
4. Unit must be grounded to the metal frame of the mobile
home.


from
back of top
ue vent to
wall

Fig. 5: Optional Top Vent Pipe Clearances
Fig. 2



Fig. 3




Fig. 4

32" minimum
32" minimum

(152mm)


 from
pipe to wall







*Measure front and side floor protection from the glass opening.

Other manuals for Harman XXV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman XXV and is the answer not in the manual?

Harman XXV Specifications

General IconGeneral
BrandHarman
ModelXXV
CategoryPellet stove
LanguageEnglish

Related product manuals