XXV Pellet Stove

1. Scrape the top holed surface and sides of the burn
pot. (Fig 39) It is not necessary to completely remove
all loose material from the burn pot. The excess will be
pushed out during the next use.
2. Loosen the (2) wing thumb screws on the lower front
angle of the burn pot. (Fig. 39)
3. Lift off the clean-out cover (Fig.40) to open the bottom
clean-out chamber. (Fig.41)
4. Clean ash buildup from inside the chamber while
cover is off. Use the scraper to tap on the top front
edge of the burn pot. This will help knock pieces of
ash, loosened by the scraping process, down through
the holes. It also helps knock scale off of the igniter
element.

The igniter is made to be removable for service
by insulated male/female wire connectors. These
connections between the hot leads (the wires inside
the burn pot) and the cold leads (the wires from the
control board) are always pulled to the rear of the
feeder body.
It is very important that these connections are to the
inside rear of the feeder body. Also, the extra wire of
the igniter wire service loop must be pulled out through
the rear of the feeder and tied up so that it will not be
damaged by any moving parts.
Fig. 41
DANGER
Disconnect the power to the unit before
removing cover.
Viewed from below through the ash pan opening.

Fig. 39
Fig. 40
   
       

WARNING



Burn pot igniter
Whenever wood is burned, there is a potential for
creosote formation. The venting system should be
inspected periodically during the heating season to
determine if a creosote buildup has occurred. If a
signicant layer of creosote has accumulated (3 mm
or more), it should be removed to reduce the risk of a
chimney or venting system re.