5. LCD: Displaying “HOT” or “COLD”
28
The LCD display will read “COLD” when the cell is reading water temps below 50° F.
The LCD display will read “HOT” when the cell is reading water temps above 140 ° F.
Inspect the cell for calcification. Clean the cell & reset
the average salt reading (pg. 10). IF the message still
appears AND the water temperature is not greater than
139F or lower than 51F, then go to 5B.
Verify the cell is not directly downstream of a running
chiller or heater. If directly downstream, this could
cause false temperature readings, otherwise replace
the TurboCell.
Inspect Cell
Upstream Equipment
To override a “COLD” message for 24 hrs., move the toggle switch from OFF, up to Super Chlorinate
(without stopping on Auto). This will override the message for 24hours. If the system reads “HOT”
it is possible the temperature sensor (within the cell) has failed and the cell will require
replacement.
“HOT” = > 140°F
“COLD” = < 50°F
Step 5B
Clean Cell Calcified Cell
Step 5A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward AquaRite series and is the answer not in the manual?

Hayward AquaRite series Specifications

General IconGeneral
CategorySalt Chlorination System
Salt Level2700-3400 ppm
Voltage120V/240V
Chlorine Output1.45 lbs/day
Pool Size40, 000 gallons
Flow Rate20 GPM
Water Temperature Range50°F - 100°F (10°C - 38°C)

Related product manuals