4 Heat & Glo • 7076-250C 7/11/2014
Curve 100
A. Installation
The house owner is responsible for ensuring that all neces-
sary national and local safety measures are observed during
installation and fi tting and also responsible for observing the
fi tting and operating instructions detailed in this manual.
When you install any kind of fi replace or stove, you must
inform the local authorities. You are also responsible for call-
ing in a chimney sweep to inspect and authorize the instal-
lation.
To ensure best-possible functionality and safety for your
installation, we advise you to call a professional fi tter. Our
Hearth and Home Dealer will be able to recommend a quali-
fi ed fi tter in your area. For information on Hearth and Home
Dealers, please go to www.hearthnhome.com.
As a reminder, all local regulations, including those refer-
ring to national and European Standards need to be com-
plied with when installing the appliance.
B. Safety
Any changes made to the product by the dealer, installer
or user could result in the product and safety functions not
functioning as intended. The same applies to the fi tting of
accessories or extra equipment not supplied by Hearth and
Home. This could also be the case if parts that are neces-
sary for the operation and safety of the stove are dismantled
or removed.
External surfaces of the appliance get hot during use and
can cause burns. Use caution around the unit even when
the unit does not appear to be in use. Different materials
can hold heat for different lengths of time.
In the event of a chimney fi re, keep the front door closed,
close all air controls, evacuate the structure and call the
local authorities from a safe location.
C. Type plates
All Heat & Glo wood-burning stoves are fi tted with a
serial plate, that specifi es the approval standards and
the distance to fl ammable materials.
1
Technical Data
Technical data and dimensions
Materials:
steel plate, cast iron, galvanized sheet, skamol
Max. wood length: 25 cm
Weight Curve 100: ca. 98 kg
Weight heat-accumulating stones: ca. 86,5 kg
Connecting piece internal diameter: 135 mm
Connecting piece external diameter: 148 mm
Approval type: Intermittent fuelling
Test in compliance with EN 13240
Basic data for the Curve - series
CO Emission at 13% O2: .18% 2262 mg/Nm3
Dust @ 13% O2: 14 mg/Nm3
Nox @ 13% O2: 70 mg/Nm3
Nominal output: 8.7 kW
Amount of smoke: 5.6 g/s
Sub-pressure EN 13240: 11.8 Pa
Recommended sub-pressure in connecting piece:
14-20 Pa
Required combustion air supply: 15.5 Nm3/h
Fuel: Wood
Fuel consumption: 2.68 kg/h
Amount of fuel: 2.10 kg
Curve 100
Effi ciency: 74%
Chimney temperature EN 13240: 410°C
Temperature in connecting piece: 410 °C
Intermittent fuelling means normal use of a wood stove. In
other words, you should let the fi re die down until only the
embers are left, before refuelling.
The EC declaration of conformity is available from www.
hearthnhome.com
Note: Be aware of the use of exhaust fans when operating
in the same room or space as the appliance, which could
affect the draft of the appliance.