11
7
Wiegand Protocol
(available when No. 6 is 1)
1: Wiegand protocol
of 26-bit;
0: Wiegand protocol
of 34-bit.
8
Matched Resistance
1: Enable;
3.3 Definition of Cable
The description of 10 cables is shown below.
Table 3-3 Description of Cable
Yellow RS-485+
Blue RS-485-
Gray Case Sensor (available for Wiegand Protocol)
White Wiegand W1 (available for Wiegand Protocol)
Orange Red LED Control (available for Wiegand Protocol)
Red PWR (DC +12V)
3.4 Wiring Cables
Purpose:
Wire the cables between controller and card reader, thus to
establish the communication between them.
Steps for RS-485 communication mode: