3.2 Wiring Cables
Wire the cables between controller and card reader, thus to establish the communicaon between
them.
3.2.1 Descripon of Cable
The descripon of 10 cables is shown below.
Table 3-2 Descripon of Cable
Color Descripon
Orange Wiegand ERR (Available for Wiegand Protocol)
Brown Wiegand OK (Available for Wiegand Protocol)
White Wiegand W1 (Available for Wiegand Protocol)
Green Wiegand W0 (Available for Wiegand Protocol)
Blue RS-485-
Yellow RS-485+
Red PWR (+12 VDC)
Black GND
Gray TAMPER Control
Purple Beep Control (Available for Wiegand Protocol)
3.2.2 Set RS-485 Communicaon Mode
Steps
1.
Set the DIP switch of No. 6 as 0.
2.
Set the DIP switch of No. 1 ~ 5 for RS-485 address and reading card mode. For details, refers to
DIP Switch Descripon .
3.
Wire the cable between controller and card reader as shown below.
DS-K1109 Series Card Reader User Manual