DS-K1T8003 Series Fingerprint Access Control Terminal
Quick Start Guide
UD12126B-C
1
2
3
Activation
Appearance
Installation
The default values of the terminal are as follows:
• The default IP address: 192.0.0.64
• The default port No.: 8000
• The default user name: admin
STRONG PASSWORD RECOMMENDED–
We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case leers, lower case leers,
numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high
security system, reseng the password monthly or weekly can beer protect your product.
Activating via Device
Power on and wire the network cable aer installaon.
You should acvate the device before the first login.
Aer powering on, the interface will be displayed as follows.
You can create the device password and confirm the password to acvate.
Exing Key
Direcon Keys
Numeric Keys/
Leer Keys
OK Key
Eding Key
Deleng
Key
ESC OK
1
2
ABC
3
DEF
4
GHI
6
MNO
7
PQRS
8
TUV
9
WXYZ
5
JKL
OK Key: Press to confirm operaons. Hold the key for 3 s to enter the login interface.
Deleting Key: Press the key to delete the entered leer or number.
Numeric Keys/Letter Keys: Enter numbers or leers.
Key 0 can also represent a space key except you are using the number input method.
Exiting Key: Press the key to exit the menu.
Direction Keys: Press , , and to move the cursor.
Editing Key: Press the key to enter the number 0. Hold the key to shi among
numbers/lowercases, numbers/uppercases and symbols.
Keypad Descriptions
©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
It includes instrucons on how to use the Product. The soware embodied in the
Product is governed by the user license agreement covering that Product.
About this Manual
This Manual is subject to domesc and internaonal copyright protecon. Hangzhou
Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual.
This manual cannot be reproduced, changed, translated, or distributed, parally or
wholly, by any means, without the prior wrien permission of Hikvision.
Trademarks
and other Hikvision marks are the property of Hikvision and are
registered trademarks or the subject of applicaons for the same by Hikvision and/or
its affiliates. Other trademarks menoned in this manual are the properes of their
respecve owners. No right of license is given to use such trademarks without express
permission.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”,
WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY
QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR
AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR
INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS
PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN
CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL
BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES
FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING
FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET
SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF
REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN
YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR
USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT
THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW,
THE LATER PREVAILS.
Data Protecon
During the use of device, personal data will be collected, stored and processed. To
protect data, the development of Hikvision devices incorporates privacy by design
principles. For example, for device with facial recognion features, biometrics data is
stored in your device with encrypon method; for fingerprint device, only fingerprint
template will be saved, which is impossible to reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in
accordance with the applicable data protecon laws and regulaons, including
without limitaon, conducng security controls to safeguard personal data, such as,
implemenng reasonable administrave and physical security controls, conduct
periodic reviews and assessments of the effecveness of your security controls.
Activating via SADP
1. Download SADP Soware: Get the SADP soware from the supplied disk or the official website. Install and run the soware.
2. Acvate Device: Check the inacve device from the device list. Create a password in the right side of the interface and confirm the password.
3. Edit Device IP Address: Check the device and manually edit the device IP address, Port No., Subnet Mask, Gateway, etc.
Activating via Client Software
1. Get the client soware from the supplied disk or the official website. Install and run the client soware.
2. Enter the Device Management page.
3. Click Device tab on the top of the right panel.
4. Click Online Device to show the online device area at the boom of the page.
The searched online devices are displayed in the list.
5. Check the device status (shown on Security Level column) and select an inacve device.
6. Click Acvate to open the Acvaon dialog.
7. Create a password in the password field, and confirm the password.
8. Click OK to acvate the device.
9. Select an acvated device in Online Device area, click on the Operaon column to open the Modify Network Parameter window. Change the
device IP address to the same subnet with your computer if you need to add the device to the client.
Display Screen
Keypad
Fingerprint Recognion Area
Card Swiping Area
Power Interface
USB Interface
Network Interface
Wiring Terminal
140 mm
30 mm
155 mm
Steps:
1. Install the gang box on the wall.
Note: Make sure the gang box screw holes match the mounng plate’s. The gang box here
is for reference only. Select an appropriate gang box to install. The gang box is not supplied.
The recommanded gang box dimension is 78 × 78 mm or 100 × 62 mm.
2. Fix the mounng plate on the gang box with two supplied screws (SC-PM4X10-IMP).
3. Route the device cable through the cable hole of the mounng plate and insert the cables
in the gang box.
4. Align the terminal with the mounng plate, and secure the terminal on the mounng plate
with two supplied socket hexagon screws (SC-KM3X10_3-SUS).
1
2
3
Steps:
1. Sck a mounng template on the wall at a required height, and drill 4 holes according to the mounng
template on the wall.
Note: The suggested distance between the device lower edge and the ground is 1.3 m.
2. Insert 4 supplied expansion sleeves of the setscrews (4_KA4×22-SUS) in the drilled holes.
3. Fix and fasten the expansion bolts in the expansion sleeves respecvely.
Note: Reserve 5.2 mm to 5.5 mm of expansion bolts outside the wall for hanging the device.
4. Align four holes of the device rear panel with the fixed screws and hang the device on the wall.
Note: The addional force shall be equal to three mes the weight of the equipment but not less than
50 N. The equipment and its associated mounng means shall remain secure during the test. Aer the
test, the equipment, including any associated mounng plate, shall not be damaged.
With Gang Box Without Gang Box
4
Device Mounng
Plate
Gang Box
Doorbell
Buon
Doorbell Button: Press the doorbell buon and the doorbell rings.
120 mm
130.6 mm
25.15 mm
66.6 mm
53.2 mm
36.5 mm
83.65 mm
68.1 mm
ESC OK
1
2
ABC
3
DEF
4
GHI
6
MNO
7
PQRS
8
TUV
9
WXYZ
5
JKL
0
M4 Expansion Bolt
Expansion Sleeve
[Number]
OK Next Input Method
Device Acvaon
Acvaon Password (8 to 16 Characters)
Notes:
1. The pictures here are for reference only. Some models do not support card swiping
funcon. For details, refer to the actual products.
2. If you enable the aendance status funcon, the OK key, the direcon key, and the
exing key can be the shortcut key of the aendance status.
0