Note
You can set 2 dierent me duraons in Area Management → Schedule & Timer .
Follow Zone
The zone acts as delayed zone when it detects triggering event during system Entry Delay,
while it acts as instant zone otherwise.
Perimeter Zone
The system will immediately alarm when it detects a triggering event
aer the system is
armed. There is a
congurable interval mer between the alarm acvaon and sounder
output "Sounder Delay Time (Perimeter Alarm) 0 to 600 Seconds". This
opon allows you to
check the alarm and cancel the sounder output during the interval me in case of false
alarm.
When the zone is armed, you can set the peripheral alarm delayed
me in Area
Management → Schedule & Timer . You can also mute the sounder in the delayed me.
Silent Panic Zone
This zone type is acve 24hrs, it is used for Panic or HUD (Hold Up Devices) not smoke
sensors or break glass detectors.
Panic Zone
The zone
acvates all the me. It is usually used in the sites equipped with panic buon,
smoke detector and glass-break detector.
Fire Zone
The zone acvates all the me with sound or sounder output when alarm occurs. It is usually
used in
re hazardous areas equipped with smoke detectors and temperature sensors.
Gas Zone
The zone acvates all the me with sound or sounder output when alarm occurs. It is usually
used in areas equipped with gas detectors (e.g., the kitchen).
Medical Zone
The zone acvates all the me with beep conrmaon when alarm occurs. It is usually used
in places equipped with medical emergency
buons.
Timeout Zone
The zone acvates all the me. The zone type is used to monitor and report the "ACTIVE"
status of a zone, but it will only report and alarm this status aer the programmed me has
expired. (1 to 599) Seconds. It can be used in places equipped with
magnec contacts that
require access but for only a short period (e.g., re hydrant box's door or another external
security box door)
Disabled Zone
Alarms will not be
acvated when the zone is triggered or tampered. It is usually used to
disable faulty detectors.
Hybrid Security Control Panel User Manual
32