5 Technical data
General technical data
Dimensions RSPM See “Dimension drawings” on page 30.
Weight RSPM20-4Z64Z6... 10.23 oz (290 g)
RSPM20-4T14T1...
RSPM22-4T14T1...
4.59 oz (130 g)
RSPM20-4T14Z6...
RSPM22-4T14Z6...
7.76 oz (220 g)
Climatic
conditions
during operation
Ambient air temperature
a
.
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Devices with operating temperature
characteristic value S (standard):
+32 °F ... +140 °F (0 °C ... +60 °C)
b
b. Hirschmann recommends to use SFP transceivers with “EEC” extension.
Devices with the operating temperature
characteristic value E and T (Extended)
c
:
−40 °F ... +158 °F (−40 °C ... +70 °C)
d
−40 °F ... +185 °F (−40 °C ... +85 °C) for 16
hours (tested in accordance with IEC 60068-
2-2)
d
c. Note the specifications for the basic device in the “User Manual Installation RSPE”.
d. Use SFP transceivers with the “EEC” extension only, otherwise the standard temperature
range applies.
Maximum inner temperature of
device (guideline)
Devices with operating temperature
characteristic value S (standard):
190 °F (88 °C)
Devices with operating temperature
characteristic value E and T (extended):
208 °F (98 °C)
Humidity 5 % ... 95 %
(non-condensing)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (−1312 ft; −400 m)
Climatic
conditions
during storage
Ambient air temperature
a
−40 °F ... +185 °F (−40 °C ... +85 °C)
Humidity 5 % ... 95 %
(non-condensing)
Air pressure min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (−1312 ft; −400 m)
Pollution degree 2
Protection
classes
Laser protection Class 1 in compliance with IEC 60825-1
Degree of protection of the
RSPE device
IP20