3.2.2 Split system - R410A Outdoor unit
RAS-(2-10)WH(V)NP(E) in combination with YUTAKI S, YUTAKI S COMBI
Model Power supply
Applicable voltage
Compressor and fan motors
MC
(A)
Max. IPT
(kW)
Cooling Heating
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RAS-2WHVNP
1~ 230V 50Hz 253 207
5.2 1.17 3.4 0.77 14 3.14
RAS-2.5WHVNP 6.8 1.54 5.3 1.21 16 3.59
RAS-3WHVNP 9.4 2.14 7.0 1.60 18 4.05
RAS-4WHVNPE 9.2 2.11 9.3 2.12 30 6.93
RAS-5WHVNPE 12.6 2.87 12.7 2.90 30 6.93
RAS-6WHVNPE 16.0 3.65 15.0 3.43 30 6.93
RAS-4WHNPE
3N~ 400V 50Hz 440 360
3.4 2.11 3.4 2.12 14 8.70
RAS-5WHNPE 4.6 2.87 4.6 2.90 14 8.70
RAS-6WHNPE 5.8 3.65 5.5 3.43 16 9.95
RAS-8WHNPE 7.1 4.41 7.3 4.58 24 15.00
RAS-10WHNPE 9.8 6.15 8.8 5.51 24 15.00
RAS-(4-6)WH(V)NP(E) in combination with YUTAKI S80
Model Power supply
Applicable voltage
Compressor and fan motors
MC
(A)
Max. IPT
(kW)
Cooling Heating
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RAS-4WHVNPE
1~ 230V 50Hz 253 207
9.2 2.11 9.3 2.12 20 6.93
RAS-5WHVNPE 12.6 2.87 12.7 2.90 25 6.93
RAS-6WHVNPE 16.0 3.65 15.0 3.43 25 6.93
RAS-4WHNPE
3N~ 400V 50Hz 440 360
3.4 2.11 3.4 2.12 14 8.70
RAS-5WHNPE 4.6 2.87 4.6 2.90 14 8.70
RAS-6WHNPE 5.8 3.65 5.5 3.43 16 9.95
3.2.3 Split system - R32 Outdoor unit
RAS-(2-3)WHVRP in combination with YUTAKI S, YUTAKI S COMBI
Model Power supply
Applicable voltage
Compressor and fan motors
MC
(A)
Max. IPT
(kW)
Cooling Heating
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RAS-2WHVRP
1~ 230V 50Hz 253 207
4.5 1.00 5.0 1.09 10.4 2.27
RAS-2.5WHVRP 5.0 1.12 5.5 1.19 12.9 2.82
RAS-3WHVRP 7.6 1.67 8.1 1.79 15.8 3.49
ELECTRICAL DATA
PMML0510 rev.1 - 10/2019