2 General data
Generalspecications
TCGB0123 rev.2 - 10/2019
40
2.4.3 Split system - Indoor unit
2.4.3.1 YUTAKI S
Model RWM-2.0NRE(-W) RWM-2.5NRE(-W) RWM-3.0NRE(-W)
Power supply - 1~ 230V 50Hz
Noise level (sound power) dB(A) 37 37 37
Nominal water
ow
WIT: 30 ºC / WOT: 35 ºC
ΔT:5ºC
m
3
/h 0.77 1.03 1.29
Cabinet
Material - Precoated galvanised steel
Colour - Pure white (RAL 9010)
Unit dimensions
Height (with connections) mm 712 (782)
Width mm 450
Depth mm 275
Packaging
dimensions
Height mm 468
Width mm 905
Depth mm 539
Packaging volume m
3
0.23
Packaging materials - Wood - Carton - Plastic
Net weight kg 35 36 37
Gross weight kg 44 45 46
Refrigerant
pipes
connection
Connection type - Flare nut connection
Liquid pipe diameter mm (in.) Ø6.35 (1/4”) Ø9.52 (3/8”)
Gas pipe diameter mm (in.) Ø15.88 (5/8”)
Space
heating pipes
connection
Connection type - Screwed connection
Shutdown valves mm (in.) G 1” (male) - G 1” (male)
Inlet pipe diameter mm (in.) G 1” (female)
Outlet pipe diameter mm (in.) G 1” (female)

Table of Contents

Other manuals for Hitachi RASM-2VRE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RASM-2VRE and is the answer not in the manual?

Hitachi RASM-2VRE Specifications

General IconGeneral
BrandHitachi
ModelRASM-2VRE
CategoryHeat Pump
LanguageEnglish

Related product manuals