EasyManuals Logo
Home>Hitachi>Heat Pump>RASM-3VRE

Hitachi RASM-3VRE User Manual

Hitachi RASM-3VRE
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
2 General data
Component data
TCGB0123 rev.2 - 10/2019
46
2.5 Component data
2.5.1 Split system - Outdoor unit
MODEL RAS-2WHVRP RAS-2.5WHVRP RAS-3WHVRP
Air heat
exchanger
Type Multi-passcross-nnedtube
Pipe material Copper
Outer diameter mm 7
Rows 2
Number of tubes in the heat exchanger 44
Fin material Aluminium
Fin pitch 1.45
Maximum operating pressure MPa 4.15
Total front area m
2
0.47
Number of heat exchanger per unit 1
Fan
Fan type Direct drive propeller fan
Fans per unit 1
Outer diameter mm 449
Revolutions rpm 790 970
Nominalairow m
3
/min 45.9 57
Motor
Shell Drip-proof type enclosure
Starting Direct current control
Power W 40
Quantity 1
Insulation class E
Compressor
Model EX118HF1 EX118HF1
GTD163UK
QA8LTH
Oil Type ACS68R ACS68R
Quantity (l) 0.75 0.75