7.8.2.9 Optional functions conguration
This menu allows to congure the optional functions for system, space heating or space cooling, DHW and Emergency operation.
DHW:
Congure the optional functions for the DHW. See detailed
information below.
Emergency operation:
Enable or disable emergency operation for space heating or DHW.
See detailed information below.
System:
Congure the optional functions for the system. See
detailed information below.
Space functions:
Congure the optional functions for the space heating or
space cooling. See detailed information below.
System optional functions
Hydraulic separator status:
Enable if there is a Hydraulic separator or a
buffer tank installed. Check that WP3 is set
in output 2 (see section “7.8.2.10 Inputs,
Outputs and Sensors conguration”)
Energy conguration:
Setup of power consumption readings. See
detailed information below.
Smart function:
To block or limit the heat pump or
increase demand due to electricity
availability. See detailed information
below.
Energy conguration
Status:
Enable or disable energy conguration options
Capacity conguration:
Due to usage of water temperature inlet and outlet
+ water ow level, an estimation of capacity can
be checked through the Operation information -
Energy data menu.
Power meter 1 or 2:
• The power meter does a real measuring of
the power consumption.
• If the power meter is enabled, it is possible
to see the information collected through the
Operation information - Energy data menu.
• If “power meter” is disabled the YUTAKI
software does an estimate consumption of
the system.
• In case of using power meter 1 or 2 input
must be congured at the Inputs menu
(see section “7.8.2.10 Inputs, Outputs and
Sensors conguration”)