GENERATING SET USE
• This type of generating set is fitted with a thermal circuit breaker which acts as a protection
against overload. If the distribution of electric current is interrupted during use, this might
be caused by an overload tripping the thermal circuit breaker. If this happens, wait a few
moments, eliminate the cause of the overload, then reset the circuit breaker by pressing
the button [1] sited near to the AC receptacles. The thermal circuit breaker is rated
according to the specifications of the machine; if it needs replacing, use an original Honda
component.
OPERATION
1. Models EC2200 B1, EC4000 B, EC6000 B: select the appropriate voltage using the
voltage selector [2].
2. Connect machines to the receptacles, taking care not to exceed the maximum current
specified for each receptacle.
3. Ensure that the circuit breaker is reset.