CAUTION:
• Do not exceed the current limit specified for any one receptacle.
• Do not modify or use the generator for other purposes than it is
intended for. Also observe the following when using the generator.
• Do not connect an extension to the exhaust pipe.
• When an extension cable is required, be sure to use a tough rubber
sheathed flexible cable (IEC 245 or equivalent).
• Limit length of extension cables; 60 m (200 feet) for cables of 1.5
mm
2
(0.0023 in
2
) and 100 m (330 feet) for cables of 2.5 mm
2
(0.0039 in
2
). Long extension cables will lower usable power due to
resistance in the extension cable.
• Keep the generator away from other electric cables or wires such as
commercial power supply lines.
GWT1 Type
When connecting an angled plug, be sure to use only a IPx4 plug.
NOTE:
• Most appliance motors require more than their rated wattage for
startup. Make sure the electrical rating of the tool or appliance does
not exceed the maximum power rating of the generator.
Maximum power is:
6.5 kVA
• For continuous operation, do not exceed the rated power.
Rated power is:
5.5 kVA
• In either case, the total power requirements (VA) of all appliances
connected must be considered.
IPx4 PLUG