T3PROGRAMMABLETHERMOSTAT
Controlform
Room
temperature
displayrange
Dimensions
(wxhxd)
Timedisplay
Timekeeping
accuracy
Program
Timesetting
resolution
Sensing
element
Temperature
Settingrange
Power
Wiring
SPECIFICATIONS
:FuzzyLogic
:From0°Cto50°C
:T3/T3M:136x97x26mm
T3R(Wireless)136x98x62mm
:24houror12hourAM/PMformat
:+/‐ 10minsperyear
:5+2ordailyschedulewith4dailytimeand
temperaturelevelchanges
:Program– 10minutesteps
:10k(@25°C)NTCthermistor
:Program:5to35°C
OFF:5°C
:Poweredby2xAAbatteries
:T3(wired)andT3M(Opentherm)terminal
blockcapableofacceptingwiredupto1.5
mm
2
T3/T3M/T3RThermostat
Power
Electricalrating
Cyclerate
Wiring
Wireaccess
Dimensions
(wxhxd)
IPclass
:230VAC
:230V~,50..60Hz,0.5Ato5Aresistence
0.5Ato3Ainductive(0.6pf)
24V~,50..60Hz,0.5Ato5Aresistence
0.5Ato3Ainductive(0.6pf
:Selectablebyapplication(seeinstaller
setup
:Terminalblockcapableofaccepting
wiresupto1.5mm
2
:Frombackvialargewallboxopening.
Frombottomwithcableclamps.
Mainswiring– left
Lowvoltagewiring‐ right
:110x110x40mm
:30
Receiverbox
Operating
temperaturerange
Shippingandstorage
temperature
Humidityrange
EMC
LVD
R&TTE
Wireaccess
ErP
:0to40°C
:‐20to55°C
:10to90%rh,non‐ condensing
:2014/30/EU
:2014/35/EU
:1995/5/EC
:Frombackvialargewallboxopening.
:ClassIV(+2%),(EU)811/2013(T4)
ClassV(+3%),(EU)811/2013(T4R)
ClassVI(+4%),(EU)811/2013(T4M)
Environmentalandstandards
Honeywell,declaresthatthisthermostatisincompliance
withtheessentialrequirementsandotherrelevant
provisionsofDirective2014/53/EU
RFoperationband
Max,power
Protocol
Comm.Range
Comm.Technology
Receiverclass
R.E.D.
:ISM(868.0‐868.6)MHz,1%dutycycle
:25mW
:Encrypted
:30minresidentialbuilding
environment
:short,highratetransmissionsto
minimiseairtimeandavoidcollisions
:RXCat2(ETSIEN300220‐1version
1.3.1)
RFcommunication