SECURING THE PREMISES
Entry/Exit Delays
Exit Delay
Exit delay begins immediately after arming the system, and gives you time to leave through the
designated exit door without setting off an alarm. A slow beeping will sound throughout the exit delay
period, if programmed. During the last 10 seconds of the exit delay fast beeps will sound as a warning
that the delay time is nearing its end. The exit beeps cannot be silenced.
Exit Alarms Exit Alarm Active
To minimize false alarms sent to the alarm monitoring company, your system may have been
programmed for this feature. Ask your installer if Exit Alarm is active for your system.
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted
when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry
delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the
message "CA" is displayed on the keypad, along with a zone number indicating the faulted zone. No
message is sent to the alarm monitoring company. To clear the exit alarm condition, the open zone
must be made re-secured; to clear the display, enter your security code and press the
OFF key.
If you do not disarm the system before the entry delay ends, and an entry/exit door or interior zone is
still open, the alarm sound continues and an "exit alarm" message is sent to the alarm monitoring
company. The message "EA" is displayed on the keypad, along with a zone number indicating the
faulted zone. The alarm will continue to sound until the system is disarmed or timeout ocurs. To stop
the alarm, the system must be disarmed by entering your security code and pressing the
OFF key; and
the message "CA" is displayed on the keypad, indicating that the alarm has been cancelled (if this
feature is enabled by the installer). To clear the display, enter your security code and press the
OFF
key a second time. An exit alarm also results if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay.
Entry Delay
Entry Delays give you time to disarm the system when you re-enter through the designated entrance
door. You must disarm the system before the entry delay period ends, or an alarm will occur. The
keypad beeps during the entry delay period, reminding you to disarm the system. There are two entry
delays (if programmed). The first is for your primary entrance and the second can be used for a
secondary entrance, where a longer delay is required to walk to the keypad to disarm the system.
You can also arm the system with no entry delay at all by using the
NO DELAY key when arming. This
can provide greater security while on the premises or while away for extended periods of time. See
ARMING THE SYSTEM section for procedure.
See your installer for delay times programmed for your system.
Exit Delay:
00-99 seconds
Entry Delay 1: 00-99 seconds Entry Delay 2: 00-99 seconds

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ADEMCO LYNXR-I Security System and is the answer not in the manual?

Honeywell ADEMCO LYNXR-I Security System Specifications

General IconGeneral
BrandHoneywell
ModelADEMCO LYNXR-I Security System
CategorySecurity System
LanguageEnglish

Related product manuals