Refer to Supplemental Information (next page) for complete descriptions of these installation steps
5-051-735-00C Page 1
FlexGuard
®
5853 Wireless Glassbreak Detector Installation Instructions
5853 Glassbreak Detector Internal Parts
CR-123A
CR-123A
Mounting Hole
Mounting Hole
Batteries
Front Tamper Switch
LED Indicators
Microphone
Sensitivity Switches
Wall Tamper (behind battery)
Test Mode pads (on PCB)
Front Cover
Latch
Break out flash
for cover screw
2
1
O
N
OF
F
5853_001-v0
Connect Batteries
Remove pull tab to connect batteries
Select Mounting Location
Wall Mount
(Top View)
WallMnt-001-V0
CeilingMnt-001-V0
Ceiling Mount: (Side View)
NOTE: If the device is ceiling mounted, the end with the
hole (Microphone end) should face the protected glass.
Set Sensitivity (Range)
SENS2
SENS1
CR-123A
CR-123A
SENS2
SENS1
5853_004-v0
ON
OFF
SENS1 & SENS2 configure sensitivity
SENSITIVITY APPROXIMATE
RANGE
SENS1 SENS2
MAX 7.6m (25 ft)
OFF OFF
MEDIUM 4.6m (15 ft)
ON OFF
LOW 3m (10 ft)
OFF ON
LOWEST 1.5m (5 ft)
ON ON
NOTE: Ranges are approximate and vary with each
room’s acoustic properties. Always verify range with an
ADEMCO GBS-7 or FlexGuard FG-701 Glassbreak
Simulator.
Enroll Detector
Refer to text and control panel's installation
instructions.
When programming the transmitter, specify:
• Input Type = 3 (Supervised RF)
• Loop Number = 1
Mount Detector
• Use mounting holes as a template to mark
mounting locations on ceiling or wall.
• If using the optional back tamper, remove
the batteries, then mark the wall tamper
location through its mounting hole.
• Mount detector using appropriate hardware.
NOTE: A screw capture feature designed to
make ceiling mounting easier will cause some
resistance when inserting the screw into the
plastic.
• Close detector cover when finished.
CR-123A
CR-123A
SENS2
SENS1
5853_003-v1
Optional Tamper Screw
3.5 mm x 38 mm
(#6 x 1-1/2")
3.5 mm x 38 mm
(#6 x 1-1/2")
3.5 mm x 25 mm
(#6 x 1")
*3.5 mm (#6)
screws works best
with the screw
retention feature.
*The screw retention feature simplifies installation: A
rib in the screw cavity lightly holds the screw in place
when installing the detector.
Test Detector Installation
Enter Test Mode using an ADEMCO GBS-7 or
FlexGuard FG-701 Glassbreak Simulator (see Testing
the Detector on the next page). To enter Test Mode
manually, short the Test Mode pads (as shown below).
CR-123A
CR-123A
SENS2
SENS1
SENS2
SENS1
5853_005-v0
TEST
TEST
Install Cover Screw (optional)
5853_006-V1
2.9 mm (#4) screw,
6 mm (1/4-in.) long