8
Registration BAD
Timed Out
Displayed if no response to the registration request is received.
Registration BAD
Pri Sub ID BAD
Indicates the city, central station, or customer number for the labeled
account(s) is not accepted. The ID information was either entered in-
correctly, or the central station failed to pre-authorize programmed ID
numbers with AlarmNet customer service.
Registration BAD
2nd Sub ID BAD
Indicates the city, central station, or customer number for the Second-
ary account is not accepted. The ID information was either entered
incorrectly, or the central station failed to pre-authorize programmed ID
numbers with AlarmNet customer service.
Registration BAD
Pri&Sec – IDs BAD
Displayed when both primary and secondary subscriber IDs are invalid.
Registration BAD
Pri ID – Need PIN
Displayed if this is a repair/replacement, or an error was made in pro-
gramming the Primary account information of the communicator for an
existing account. This prompt appears for 2 seconds. See the Replac-
ing an existing communicator section below for further displays.
Registration BAD
2nd ID – Need PIN
This prompt is displayed if this is a repair/replacement, or an error was
made in programming the Secondary account information of the com-
municator for an existing account. This prompt appears for 2 seconds.
See the Replacing an existing communicator section below for further
displays.
Registration BAD
Pri&2nd – Need PIN
This prompt is displayed if this is a repair/replacement, or an error was
made in programming BOTH the Primary and Secondary account in-
formation of the communicator for an existing account. This prompt
appears for 2 seconds. See the Replacing an existing communicator
section below for further displays.
Replacing an existing communicator
Enter PIN#
This prompt appears after pressing the [Shift] and down arrow [
] on
the 7720P.
Note: If it is necessary to exit registration mode, press ESC from the
7720P programming tool.
Enter a 4-digit alphanumeric PIN number provided by your central sta-
tion, your dealer or an authorized AlarmNet representative.
Press the [Enter] key.
Registering …
The registration message is sent and the unit waits for acknowledge-
ment.
Registration
SUCCESS
If the PIN is valid, the new communicator is registered and the old unit
unregistered. Additionally, AlarmNet sends a substitution alarm to the
central station.