A-2 www.hp.com Hardware Reference Guide
Specifications
✎
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea
level, no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may
be limited by the type and number of options installed.
Power Supply
Operating Voltage Range* 90–264 VAC 90–264 VAC
Rated Voltage Range 100–240 VAC 100–240 VAC
Rated Line Frequency 50–60 Hz 50–60 Hz
Power Output 240 W 240 W
Rated Input Current (maximum)* 5A @ 100 VAC 2.5A @ 200 VAC
Heat Dissipation
Maximum 1260 BTU/hr 318 kg-cal/hr
Typical (idle) 340 BTU/hr 86 kg-cal/hr
*This system utilizes an active power factor corrected power supply. This allows the system to
pass the CE mark requirements for use in the countries of the European Union. The active power
factor corrected power supply also has the added benefit of not requiring an input voltage
range select switch.
HP Compaq Slim Tower (Continued)