28
ProCurve Switch vl Modules
Specifications
Cables
Twisted-Pair Cables
Note on 1000Base-T Cable Requirements. The Category 5 networking
cables that work for 100Base-TX connections should also work for
1000Base-T, as long as all four pairs are connected. But for the most reliable
connections you should use cabling that complies with the Category 5e
specifications, as described in Addendum 5 to the TIA-568-A standard (ANSI/
TIA/EIA-568-A-5).
Because of the increased speed provided by 1000Base-T (Gigabit-T), network
cable quality is more important than for either 10Base-T or 100Base-TX.
Cabling plants being used to carry 1000Base-T networking must comply with
the IEEE 802.3ab standards. In particular, the cabling must pass tests for
Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT).
Additionally, unlike the cables for 100Base-TX, the 1000Base-T cables must
pass tests for Equal-Level Far-End Crosstalk (ELFEXT), Multiple Disturber
ELFEXT, and Return Loss.
When testing your cabling, be sure to include the patch cables that connect
the switch and other end devices to the patch panels on your site. The patch
cables are frequently overlooked when testing cable and they must also
comply with the cabling standards.
Port Type Cable Specifications Maximum Length
10 Mbps Operation Category 3, 4, or 5 100-ohm balanced unshielded twisted-pair
(UTP) or shielded twisted-pair (STP) cable, complying with IEEE
802.3 10Base-T specifications, fitted with RJ-45 connectors
100 meters
100 Mbps Operation Category 5 100-ohm balanced UTP or STP cable, complying
with IEEE 802.3u 100Base-TX specifications, fitted with RJ-45
connectors
100 meters
1000 Mbps Operation Category 5e 100-ohm balanced UTP or STP cable, complying
with IEEE 802.3ab 1000Base-T specifications, fitted with RJ-45
connectors (see “Note on 1000Base-T Cable Requirements”,
below)
100 meters

Other manuals for HP ProCurve J8766A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve J8766A and is the answer not in the manual?

HP ProCurve J8766A Specifications

General IconGeneral
BrandHP
ModelProCurve J8766A
CategorySoftware
LanguageEnglish

Related product manuals