System Unit Rack
System Unit RackSystem Unit Rack
System Unit Rack
Dimensions
DimensionsDimensions
Dimensions
(H x W x D)
(with bezel)
6.94 x 19.0 x 26.5 in (17.6 x 48.3 x 67.3 cm)
Weight
WeightWeight
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
100.0 lb (45.4 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
71.0 lb (32.2 kg)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 - 132 VAC,
180 - 264 VAC
Rated Input Current
10 A (at 100 VAC),
7.8 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
964 W (at 100 VAC),
1412 W (at 240 VAC)
BTU Rating
BTU RatingBTU Rating
BTU Rating
Maximum
3355 BTU/hr (at 100 VAC),
4914 BTU/hr (at 200 VAC)
Power Specifications
Power SpecificationsPower Specifications
Power Specifications
NOTE:
NOTE:NOTE:
NOTE:
To review typical system power ratings use the HP Power Advisor
which is available online located at url:
www.hp.com/go/proliant-energy-
efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL580 G5
- Follow the instructions of the next screens.
Power Supply Output
Power Supply Output Power Supply Output
Power Supply Output
(per
power supply)
Rated Steady-State Power
800 W (at 100 VAC),
1200 W (at 200 VAC)
Maximum Peak Power
800 W (at 100 VAC),
1200 W (at 200 VAC)
System Inlet Temperature
System Inlet TemperatureSystem Inlet Temperature
System Inlet Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
QuickSpecs
HP ProLiant DL580 Generation 5 (G5)
HP ProLiant DL580 Generation 5 (G5)HP ProLiant DL580 Generation 5 (G5)
HP ProLiant DL580 Generation 5 (G5)
Technical Specifications
DA - 12770 Worldwide — Version 44 — November 23, 2010
Page 52

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL580 Generation 5 (G5) and is the answer not in the manual?

HP ProLiant DL580 Generation 5 (G5) Specifications

General IconGeneral
Form Factor4U Rack
ProcessorUp to four Intel Xeon 7300 series processors
MemoryUp to 256 GB PC2-5300 Fully Buffered DIMMs
StorageUp to eight 2.5-inch SAS or SATA hard drives
RAIDHP Smart Array P400i
NetworkEmbedded NC373i Multifunction Gigabit Network Adapter
Power SupplyUp to two 1200W hot-plug power supplies
Operating System SupportMicrosoft Windows, Red Hat Linux, SUSE Linux, VMware